To do...
Specify the maximum LSP age
2)
Specify the LSP refresh interval and generation interval
Each router needs to refresh LSPs generated by itself at a configurable interval and send them to other
routers to prevent valid routes from being aged out. A smaller refresh interval speeds up network
convergence but consumes more bandwidth.
When the network topology changes, for example, a neighbor is down/up, or the interface metric,
system ID or area ID is changed, the router generates an LSP after a configurable interval. If such
changes occur frequently, excessive LSPs are generated, consuming a large amount of router
resources and bandwidth; in this case, you can adjust the LSP generation interval.
Follow these steps to specify the LSP refresh interval and generation interval:
To do...
Enter system view
Enter IS-IS view
Specify the LSP refresh
interval
Specify the LSP generation
interval
3)
Specify LSP sending intervals
If a change occurs in the LSDB, IS-IS advertises the changed LSP to neighbors. You can specify the
minimum interval for sending such LSPs.
On a P2P link, IS-IS requires an advertised LSP be acknowledged. If no acknowledgement is received
within a configurable interval, IS-IS will retransmit the LSP.
Follow these steps to configure LSP sending intervals:
To do...
Enter system view
Enter interface view
Specify the minimum interval
for sending LSPs and the
maximum LSP number that can
be sent at a time
Specify the LSP retransmission
interval on a P2P link
Use the command...
timer lsp-max-age seconds
Use the command...
system-view
isis [ process-id ] [ vpn-instance
vpn-instance-name ]
timer lsp-refresh seconds
timer lsp-generation maximum-interval
[ initial-interval [ second-wait-interval ] ]
[ level-1 | level-2 ]
Use the command...
system-view
interface interface-type
interface-number
isis timer lsp time [ count
count ]
isis timer retransmit
seconds
1-27
Remarks
Optional
1200 seconds by default
Remarks
––
––
Optional
900 seconds by
default
Optional
2 seconds by
default
Remarks
––
––
Optional
By default, the minimum interval is
33 milliseconds, and the maximum
LSP number that can be sent at a
time is 5.
Optional
5 seconds by default