3Com S7906E Configuration Manual page 335

S7900e family release 6600 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

To do...
Enable the dying gasp alarm
function
Enable the error frame period
alarm function
Configure the window size and
threshold for error frame period
alarms
Enable the error frame alarm
function
Configure the window size and
threshold for error frame alarms
Use the command...
alarm oam dying-gasp
enable
alarm oam
error-frame-period enable
alarm oam
error-frame-period { window
window | threshold threshold }
*
alarm oam error-frame
enable
alarm oam error-frame
{ window window | threshold
threshold } *
5-4
Remarks
Optional
The system generates a dying
gasp alarm when a system
error, a data loading error, or
any other nonreversible errors
occur.
Optional
The system generates an error
frame period alarm when the
number of error frames in a
specific period (that is, the
window size) exceeds the
corresponding predefined
threshold.
By default, this function is
enabled.
Optional
When the alarm threshold is set
to 0, a lot of alarms are
generated immediately. Since
alarm events are carried in the
OAM packets, a lot of OAM
packets are generated. In this
case, OAM packets may be
lost.
By default, the window size is 1
second, and the alarm
threshold is 20 frames.
Optional
The system generates an error
frame alarm when the number
of error frames in a specific
time period (that is, the window
size) exceeds the
corresponding predefined
threshold.
By default, this function is
enabled.
Optional
When the alarm threshold is set
to 0, a lot of alarms are
generated immediately. Since
alarm events are carried in the
OAM packets, a lot of OAM
packets are generated. In this
case, OAM packets may be
lost.
By default, the window size is
10 seconds, and the alarm
threshold is 20 frames.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

S7910eS7906e-vS7903eS7903e-sS7902e

Table of Contents