Configuring Alarms On An Onu Port - 3Com S7906E Configuration Manual

S7900e family release 6600 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

To do...
Enable the ONU over limitation
alarm function

Configuring Alarms on an ONU Port

Follow these steps to configure alarms on an ONU port:
To do...
Enter system view
Enter ONU port view
Enable the error symbol period
alarm function
Enable the error frame period
alarm function
Configure the window size and
threshold for error frame period
alarms
Use the command...
alarm onu-over-limitation
enable
Use the command...
system-view
interface onu
interface-number
alarm oam
error-symbol-period enable
alarm oam
error-frame-period enable
alarm oam
error-frame-period { window
window | threshold threshold }
*
5-11
Remarks
Optional
The system generates an ONU
over limitation alarm when the
total number of ONUs
connected with the OLT
exceeds the limit.
By default, this function is
enabled.
Remarks
Optional
The system generates an error
symbol period alarm when the
number of error frames in a
specific period (that is, the
window size) exceeds the
corresponding predefined
threshold.
By default, this function is
enabled.
Optional
The system generates an error
frame period alarm when the
number of error frames in a
specific period (that is, the
window size) exceeds the
corresponding predefined
threshold.
By default, this function is
enabled.
Optional
When the alarm threshold is set
to 0, a lot of alarms are
generated immediately. Since
alarm events are carried in the
OAM packets, a lot of OAM
packets are generated. In this
case, OAM packets may be
lost.
By default, the window size is 1
second, and the alarm
threshold is 20 frames.