Troubleshooting Sflow Configuration; The Remote Sflow Collector Cannot Receive Sflow Packets - 3Com 4500G Family Configuration Manual

24/48 port
Hide thumbs Also See for 4500G Family:
Table of Contents

Advertisement

Collector
Interval(s): 30
sFlow Port Information:
Interface
Direction
Eth1/1
In/Out

Troubleshooting sFlow Configuration

The Remote sFlow Collector Cannot Receive sFlow Packets

Symptom
The remote sFlow collector cannot receive sFlow packets.
Analysis
sFlow is not enabled globally because the sFlow agent or/and the sFlow collector is/are not
specified.
No port is enabled with sFlow to sample data.
The IP address of the sFlow collector specified on the sFlow agent is different from that of the
remote sFlow collector.
No IP address is configured for the Layer 3 interface on the device, or the IP address is configured,
but the UDP packets with the IP address being the source cannot reach the sFlow collector.
The physical link between the device and the sFlow collector fails.
Solution
1)
Check whether sFlow is correctly configured by displaying sFlow configuration with the display
sflow command.
2)
Check whether the correct IP address is configured for the device to communicate with the sFlow
collector.
3)
Check whether the physical link between the device and the sFlow collector is normal.
IP:3.3.3.2
Port:6343
Rate
Mode
100000
Random
1-4
Status
Active

Hide quick links: