Configuring Alarms on an OLT Port

Follow these steps to configure alarms on an OLT port:
To do...
Enter system view
Enter OLT port view
Enable the bit error rate alarm
function
Use the command...
alarm registration-error
enable
alarm remote-stable enable
alarm oam-vendor-specific
enable
alarm onu-over-limitation
enable
Use the command...
system-view
interface olt interface-number
alarm bit-error-rate enable
5-6
Remarks
Optional
The system generates a
registration error alarm when
an error occurs during the
registration of an ONU.
By default, this function is
enabled.
Optional
The system generates a
remote stable alarm when an
ONU misuse occurs in the
system, for example, when an
OAM 2.0 ONU and an OAM 3.3
ONU are mixed in the same
system. (All ONUs in the same
system must adopt the same
OAM version). This alarm is
generated at the ONU side and
will be reported to the OLT.
By default, this function is
enabled.
Optional
This alarm is customized by
vendors.
By default, this function is
enabled.
Optional
The system generates an ONU
over limitation alarm when the
total number of ONUs
connected with the OLT
exceeds the limit.
By default, this function is
enabled.
Remarks
Optional
The system generates a bit
error rate alarm when the total
number of error bits or bit error
rate of the data transferred
between the OLT and ONUs
exceeds the alarm threshold.
By default, this function is
enabled.