Configuring the PoE
Monitoring Function
Configuring a Power
Alarm Threshold for the
Upgrading PSE
Processing Software
Online
To do...
Configure
Configure the power
the power
priority for the PoE
priority for a
interface in PoE interface
PoE
view
interface.
Configure the power
priority for the PoE
interface in PoE
configuration file view
Configure a PD power management
priority policy
The PoE monitoring function involves monitoring of PoE power, PSE and PD.
Monitoring PoE power means monitoring the voltage of the PoE power.
When the current power utilization of the PSE is above or below the alarm
threshold for the first time, the system will send a Trap message.
When the PSE starts or stops supplying power to a PD, the system will send a
Trap message, too.
Follow these steps to configure a power alarm threshold for the PSE:
PSE
To do...
Enter system view
Configure a power
alarm threshold for
the PSE
You can upgrade the PSE processing software online in either of the following
modes:
refresh mode
This mode enables you to update the PSE processing software without deleting it.
Normally, you can upgrade the PSE processing software in the refresh mode
through the command line.
full mode
This mode deletes the PSE processing software and reloads it. When the PSE
processing software is damaged (in this case, you can execute none of PoE
commands successfully), you can upgrade the PSE processing software in full
mode to restore the PSE function.

Configuring the PoE Monitoring Function

Use the command...
interface
interface-type
interface-number
poe priority { critical |
high | low }
poe-profile
profile-name [ index ]
poe priority { critical |
high | low }
poe pd-policy priority Optional
Use the command...
system-view
poe utilization-threshold
utilization-threshold-value
[ pse pse-id ]
Remarks
Use either approach.
By default, the power
priority of a PoE
interface is low.
By default, no PD
power management
priority policy is
configured.
Remarks
-
Optional
By default, the power alarm threshold
for the PSE is 80%.
The support of the pse pse-id
argument varies with devices.