VoFR Configuration Example
2397
2 Configure Router B.
# Create a new frame relay class "VoFR" and set the maximum amount of voice
bandwidth.
<RouterB> system-view
[RouterB] fr class vofr
[RouterB-fr-class-vofr] voice bandwidth 32000 reserved
[RouterB-fr-class-vofr] quit
# Enter interface Serial 1/0 view and configure the encapsulation format.
[RouterB] interface serial 1/0
[RouterB-Serial1/0] link-protocol fr ietf
# Enter DLCI 100 view and set the frame relay class to VoFR for DLCI.
[RouterB-Serial1/0] fr dlci 100
[RouterB-fr-dlci-Serial1/0-100] fr-class vofr
# Specify the call control protocol to be used by DLCI 100 as Huawei-compatible
(DTE).
[RouterB-fr-dlci-Serial1/0-100] vofr huawei-compatible dte
[RouterB-fr-dlci-Serial1/0-100] quit
[RouterB-Serial1/0] quit
# Configure the VoFR entity (0101001).
[RouterB] voice-setup
[RouterB-voice] dial-program
[RouterB-voice-dial] entity 010 vofr
[RouterB-voice-dial-entity10] match-template 0101001
[RouterB-voice-dial-entity10] address vofr-dynamic serial 1/0 100
[RouterB-voice-dial-entity10] quit
# Configure the local POTS entity (07552001).
[RouterB-voice-dial] entity 2001 pots
[RouterB-voice-dial-entity2001] match-template 07552001
[RouterB-voice-dial-entity2001] line 2/0
Nonstandard-Compatibl
Network requirements
e VoFR
Telephone A (010-1001) attached to voice Router A in City A communicates with
Telephone B (0755-2001) attached to voice Router B in City B over a frame relay
network. Router B is an industry-leading router. Router A is a Huawei-3Com
router.
Router A adopts the nonstandard-compatible call control protocol.