14.12 Safety Integrated
Parameters
The following list contains the parameters of the "Safe Stop 1 with braking ramp monitoring
(SS1-r)" function.
Number
p1135[0...n]
p9560
p9560
p9581
p9581
p9582
p9583
p9603.0...1
p9604.0...30
p9606
r9714[0...4]
r9714[0...4]
r9720.0...15
r9722.0...15
c10023
r10353.0...17
668
Transition to STO
Deselection of SS1
Signal change at ON/OFF1
from 1 to 0
Signal change at ON/OFF1
from 0 to 1
Name
OFF3 ramp-down time
SI STO shutdown velocity
SI STO shutdown velocity
SI SBR reference velocity
SI SBR reference velocity
SI SAM/SBR delay time
SI SBR reference time
SI control
SI enable
SI SS1 function specification
SI diagnostics velocity
SI diagnostics velocity
SI control word
SI status signals
SI SS1 input terminal
SI SS1 select cause
SBR ends as soon as the actual speed value is below the STO
switch-off speed (p9560).
The converter activates STO.
The converter activates STO even if SS1 is deselected in the
meantime.
The converter signals the status "STO active" (r9722.0).
STO interrupts the torque-generating supply of energy to the
motor and prevents the motor from unexpectedly restarting.
The motor coasts down to a standstill.
The converter detects deselection of SS1.
The converter deactivates STO.
The converter is ready to start again.
The motor starts again.