• Offset can be set
Parameter p0783 determines the offset for the analog output.
• Scaling can be set
The converter uses a scaling characteristic to convert the value range -100% ... 100% of the
internal signal to the voltage range 0 V ... 10 V or current range 4 mA ... 20 mA, whichever
is suitable. The two points (x1, y1) and (x2, y2) define the scaling characteristic.
Figure 14-39
Parameters
The following list contains the parameters of the "Analog outputs" function.
Number
c0771[0]
r0772[0]
p0773[0]
r0774[0]
p0775[0]
p0776[0]
p0777[0]
p0778[0]
p0779[0]
p0780[0]
c0782[0]
p0783[0]
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
Scaling of the analog output
Name
Analog output signal
Analog output actual output value referred
Analog output smoothing time constant
Analog output actual output voltage/current
Analog output, activate absolute value generation
Analog output type
Analog output characteristic value x1
Analog output characteristic value y1
Analog output characteristic value x2
Analog output characteristic value y2
Analog output inversion
Analog output offset