Functions
14.8 Inputs/outputs
Table 14-65
Parameters
The following list contains the parameters of function "I/O presetting Standard I/O with analog
setpoint".
Number
r0722.0...22
c0730
c0731
r0755[0...1]
c0771[0]
c0840[0...n]
c1070[0...n]
c1113[0...n]
c2103[0...n]
422
Signal interconnection of the inputs and outputs
Input Signal interconnection
DI 0
c0840[0] = r0722.0
DI 1
c1113[0] = r0722.1
DI 2
c2103[0] = r0722.2
AI 0 c1070[0] = r0755[0]
Name
Digital inputs status
Signal for terminal DO 0
Signal for terminal DO 1
Analog inputs, actual value in percent
Analog output signal
ON / OFF (OFF1)
Main setpoint
Setpoint inversion
1st acknowledge faults
Output Signal interconnection
DO 0
DO 1
AO 0 c0771[0] = r0021
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
c0730 = r0052.3
c0731 = r0052.2
Unit
 
 
 
[%]
 
 
 
 
 
SINAMICS G220 converter