Siemens SINAMICS G220 Operating Instructions Manual page 410

Table of Contents

Advertisement

Functions
14.6 Ethernet/IP communication
Attrib‐
ute ID
10
11
Supported services: Get attribute all, get attribute single
1)
408
Service
Type
1)
5
get,
Struct of
get_and_clea
UINT32
r
UINT32
UINT32
UINT32
UINT32
UINT32
UINT32
UINT32
UINT32
UINT32
UINT32
UINT32
6
get
Struct of
UINT16
UINT16
get
String
get
Name
Media Counters
Alignment Errors
FCS Errors
Single Collisions
Multiple Collisions
SQE Test Errors
Deferred Transmissions
Late Collisions
Excessive Collisions
MAC Transmit Errors
Carrier Sense Errors
Frame Too Long
MAC Receive Errors
Interface Control
Control Bits
Forced Interface Speed
Interface_Label
Interface Capability
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
Value/explanation
Media-specific counters
Structure received, which does
not match the number of octets
Structure received, which does
not pass the FCS check
Structure successfully transmit‐
ted, precisely one collision
Structure successfully transmit‐
ted, multiple collisions
Number of SQE errors
First transmission attempt de‐
layed
Number of collisions that occur‐
red delayed by 512 bit timers to
the request
Transmission unsuccessful as a
result of intensive collisions
Transmission unsuccessful as a
result of an internal MAC sublay‐
er transmission error.
Number of errors when attempt‐
ing to send a request frame,
where the transmission condi‐
tion was lost or was not assigned
Structure too large
Transmission unsuccessful as a
result of an internal MAC sublay‐
er receive error.
Interface-Label
Bit 0: Manual Setting
Bit 1: Auto-negotiate
Bit 2: Auto-MDIX
Bit 3: Manual Speed/Duplex
Bits 4 – 31: reserved
Rest: Speed/Duplex options