Functions
14.10 Closed-loop drive control
Table 14-78
Low-pass with reduction
Filter parameters
Characteristic frequency
f
= 500 Hz
Abs
Damping D = 0.7
Reduction Abs = -10 dB
Settings for the general 2nd order filter:
•
Denominator natural frequency f
•
Numerator natural frequency
•
Denominator damping D
•
Numerator damping: D
Parameters
The following list contains the parameters of the "Current setpoint filter" function.
Number
c1655[0...4]
p1656[0...n].0...4
p1657[0...n]
p1658[0...n]
p1659[0...n]
p1660[0...n]
p1661[0...n]
p1662[0...n]
p1663[0...n]
p1664[0...n]
p1665[0...n]
p1666[0...n]
p1699
552
Amplitude response
= f
(start of reduction)
N
Abs
= 0.7
N
= 0.7
Z
Name
Current setpoint/Speed actual value filter nat. frequency tuning
Current setpoint/Speed actual value filter activation
Current setpoint filter 1 type
Current setpoint filter 1 denominator natural frequency
Current setpoint filter 1 denominator damping
Current setpoint filter 1 numerator natural frequency
Current setpoint filter 1 numerator damping
Current setpoint filter 2 type
Current setpoint filter 2 denominator natural frequency
Current setpoint filter 2 denominator damping
Current setpoint filter 2 numerator natural frequency
Current setpoint filter 2 numerator damping
Filter data acceptance