Led Rdy And Led Com - Siemens SINAMICS G220 Operating Instructions Manual

Table of Contents

Advertisement

15.1.4

LED RDY and LED COM

Response of the LEDs
RDY
COM
Not rele‐
vant
Green
Not rele‐
vant
Green
Green
Green
Green
Green
Not rele‐
vant
Green
Green
Orange
 
Orange
Orange
Orange
 
Orange
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
Description
Converter is ready for operation and is fault free.
Cyclic communications running.
Possible causes
Firmware is being updated.
All user-defined settings are reset to the factory
setting.
Firmware update completed
The converter is waiting.
All user-defined settings are reset to the factory
setting.
 
PROFIenergy energy saving mode is active.
Commission or restore factory settings using the
commissioning tool
Temporary state after the supply voltage is switch‐
ed on: firmware being loaded and initialized.
Possible causes
Temporary state after the supply voltage is
switched on
Restart
Converter detection via DCP flashing.
Remedy
 
 
 
Switch the converter supply voltage off and on.
Switch the converter supply voltage off and on.
 
 
 
 
 
System messages
15.1 LEDs
737