Basic Parameterization Together With A Simatic Controller - Siemens SINAMICS G220 Operating Instructions Manual

Table of Contents

Advertisement

4. Establish an online connection between Startdrive and the target device
5. Make basic settings online via the guided quick startup in editing mode
– Make basic settings in quick startup screen forms
– Perform optimization
Result:
The motor rotates.
More information
Detailed information can be found in the information system of the TIA Portal in Chapter
"Configuring SINAMICS G220 drives".
11.3.4

Basic parameterization together with a SIMATIC controller

Procedure
If you want to commission the SINAMICS drive together with a SIMATIC control system, the
optimum sequence for basic parameterization is as follows:
1. Create or open the project with Startdrive
2. Create the device configuration in Startdrive offline
– Insert the SINAMICS drive into the project and specify it
– Create and specify SINAMICS components and make detailed settings
– Insert the SIMATIC controller into the project and specify it
– Network the SIMATIC controller and drive
– Optional: Configure user administration and make protection settings for the drive and
– Insert a technology object into the SIMATIC controller
– Interconnect the technology object with the drive
3. Download project data to the target devices
4. Establish an online connection between Startdrive and the target device
5. Make basic settings online via the guided quick startup in editing mode
– Make basic settings in quick startup screen forms
– Perform optimization
Result:
The motor rotates.
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
control
11.3 Device configuration and basic parameterization
Commissioning (Startdrive)
285