i-PRO WJ-NX510K Series Operating Instructions Manual page 81

Hide thumbs Also See for WJ-NX510K Series:
Table of Contents

Advertisement

[Setup via recorder's main monitor]
[Terminal output]
Choose whether or not to output an alarm signal from the alarm output terminal of the
ALARM/CONTROL connector on the recorder's rear panel when an alarm signal is received.
On: Outputs the alarm signals from the alarm output terminal.
Off: Does not output alarm signals.
Default: On
[Terminal input]
Select the terminal status for supplying an alarm signal to the alarm terminal.
N.O. (Normally Open): Signals will be supplied when short-circuited.
N.C. (Normally Close): Signals will be supplied when open-circuited.
Default: N.O.
[Name]
Enter the names of terminal alarms using the on-screen keyboard (up to 16 characters).
[Back] button
Click the button after completing the settings. The screen returns to the [Event setup] tab.
Set up camera site alarm [Advanced camera site alarm setup]
Set up the action to be taken when a TCP alarm notification received from a camera
triggers camera site alarm.
Note:
● The alarm history and the body of e-mail notifications are displayed with
the name you set.
Note:
● Refer to the following section for further information about the camera
preset positions.
Operate the camera
77