Olivetti d-Color MF4003 Service Manual page 88

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
[2]
[1]
(2)  Reinstall procedure
[2]
[1]
[3]
4. Close the right door.
5. Carry out the [Service Mode] -> [Counter] -> [Life] -> [New Release].
3.1.12  Replacing the fusing unit
• The temperature gets high in the vicinity of the fusing unit.
You may get burned when you come into contact with the
area.
Before replacement operations, make sure that more
than 20 minutes have elapsed since the main power
switch was turned off.
1. Open the right door.
Service Manual
2. Unlock the lock levers [1] of the transfer roller unit (at two places).
3. Holding onto the lock levers [1] (at two places), remove the transfer roller unit
1. Holding onto the lock levers [1] (at two places), mount the new transfer roller
2. Insert two protrusions [1] of the transfer roller unit into the center of the
[3]
3. Lock the lock levers [3] (at two places).
[1]
[2]
CAUTION
E MAINTENANCE > 3. Periodical replacement procedure
[2].
unit [2].
NOTE
▪ The transfer roller unit must be engaged in the transfer roller unit
supporter.
pressure spring [2].
NOTE
▪ Make sure that the levers are locked in position both at front and
rear.
E-12
Y119930-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303

Table of Contents