Olivetti d-Color MF4003 Service Manual page 385

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
Setting item
Network Packet
If network packet information is necessary, select "ON."
Acquisition function
Select the functions to be covered when obtaining debug logs.
This item will not be displayed when [Network Packet] is set to "ON."
Network Packet Capture
If [Network Packet] is set to "ON," configure [Capture Filter Settings]
and [Capture Settings].
This item will not be displayed when [Network Packet] is set to "OFF."
By Job
Set the number of jobs handled as a unit (the number of jobs by which
debug information is acquired).
Individual Command
Register and execute individual debug commands.
Command Set
Install a command set and execute it.
Timing of Saving Debug Information in Each Mode
• Debug information is stored at the timings described below.
Modes
Basic mode
When trouble occurs
When there is no job
During transition to energy save mode (sleep mode or low power mode)
When authentication fails
When [Debug Log Output] -> [Shared Memory -> HDD] is performed
manually
Enhance mode
Save as needed.
3.4  Remote Log Retrieval
• Use the WebDAV server to retrieve remote access logs.
• Downloads the command set from the server configured from [Remote Log Server Settings] -> [Command Set Acquisition Pt.] at the timing
configured from [Time Setting] and [polling].
• If the command set successfully downloads, logs and settings data is retrieved in accordance with the command set, and the log files and
settings data files are saved on the server configured from [Remote Log Server Settings] -> [Log Save Destination].
Setting value
ON
OFF
Time Setting
• Downloads the command set at the specified time and retrieves/saves the logs and settings data.
• This item will be displayed only when [ON] is set to Remote Log settings.
Setting value
ON
OFF
• *: When [Yes] selected, configure the time settings.
Polling
• Downloads the command set at each specified time and retrieves/saves the logs and settings data.
• This item will be displayed only when [ON] is set to Remote Log settings.
Setting value
ON (*)
OFF
• *: When [ON] selected, configure the polling interval settings.
Retrieve Log Information
• Immediately downloads the command set and retrieves/saves the logs and settings data.
NOTE
▪ This is displayed only when [Administrator] -> [Security] -> [Security Details] -> [Export Debug Log] is set to "Allow."
3.5  Remote Log Server Settings
Command Set Acquisition Pt.
• Configures the server from which command sets as used for [Remote Log Retrieval] are retrieved.
• Touch [Copy Setting] after settings parameters are selected to copy the settings to the destination as configured from [Log Save
Destination].
Setting item
Host Name
Set the host name of the WebDAV server.
File Path
Set the file path used in the WebDAV server communication.
Y119930-3
J BILLING SETTING/ENHANCED SECURITY/DEBUG SETTINGS > 3. DEBUG
Contents
Saving timing
Contents
J-31
Setting value
OFF/ON
Select All, Copy, Printer, User Box, Net/
Scan, Web Connection, FAX, Net Fax,
and Authentication
-
1 - 100
-
-
Save Destination
Main body storage
USB memory or Main body storage
Default setting
Default setting
Default setting
Setting value
Alphanumeric characters
and symbols up to 253
characters
142 characters maximum