d-Color MF4003/MF3303
Create a configuration file
1. Select [Service Mode] -> [Machine Update Setting] -> [Machine Auto Update Setting] -> [Machine Export Setting].
2. Insert a USB memory into the USB port.
3. Enter a password.
NOTE
▪ The password specified at above step 3 must be set beforehand by selecting [Service Mode] -> [Machine Update Setting] ->
[Machine Auto Update setting] -> [Machine Update Password].
4. Select [START].
5. [Result: OK] will be displayed.
6. Complete the data export.
7. Store the export file to the directory described in C_UpdateList.ini.
Create the Software switch setting/Engine FW DipSW setting file
• Create CSV files for the data with the required switch number as SoftwareDipSW.csv and EngineDipSW.csv.
• Store the file to the directory described in C_UpdateList.ini.
A sample of SoftwareDipSW.csv
Example
Description
A row
Software switch number
B row
Set 1 on the bit to be overwritten (bit7 to bit0 from left side)
C row
Set 1 or 0 for new setting at selected bit(s) on B row. (bit7 to bit0 from left side)
A sample of EngineDipSW.csv
Example
Description
A row
Engine FW DipSW number
B row
0 (not select) or 1 (select)
Create the user DB data file
1. Create UsbExportData_Auth.tar with a making tool of user DB data.
2. Store created file (UsbExportData_Auth.tar) to the directory described in C_UpdateList.ini.
(3)  Auto Update setting
• Obtain the MFP update file from the program server, and configure settings to update the machine at the specified time.
• This function is same as that of the [Administrator] -> [Network], but it will not be used together with the function of the service mode.