Olivetti d-Color MF4003 Service Manual page 480

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
E7-2
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of DF CIS or the CIS cable if faulty.
3. Correct the mounting of CPUB if faulty.
4. Correct the mounting of BASEB or the connection of connectors if faulty.
5. Replace the CIS cable.
6.
Replace the DF CIS module assy.
7.
Replace CPUB.
8.
Replace BASEB.
4.23  E8-1
Contents
Error code
E8-1
Target device
DF control board
Diagnosis item
MINET communication check
Reason of error
ADF microcomputer communication failure
Relevant electrical parts
Connection cable
DF control board (DFCB)
CPU board (CPUB)
Base board (BASEB)
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of DFCB or the connection of connectors if faulty.
3. Correct the mounting of CPUB if faulty.
4. Correct the mounting of BASEB or the connection of connectors if faulty.
5. Correct the connection of the connection cable if faulty.
6. Replace the connection cable.
7.
Replace DFCB.
8.
Replace CPUB.
9.
Replace BASEB.
4.24  E11-1, E11-2
Contents
Error code
E11-1, E11-2
Target device
CPU board
Diagnosis item
E11-1
E11-2
Reason of error
E11-1
E11-2
Relevant electrical parts
CPU board (CPUB)
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of CPUB if faulty.
3.
Replace CPUB.
4.25  E12-1, E12-2
Contents
Error code
E12-1, E12-2
Target device
PCIe
Diagnosis item
E12-1
E12-2
Reason of error
PCIe device error
Relevant electrical parts
E12-1, E12-2
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of CPUB if faulty.
3.
Replace CPUB.
Service Manual
L TROUBLESHOOTING > 4. TROUBLESHOOTING USING SELF-DIAG. (FULL)
Base board (BASEB)
DF CIS module (DF CIS)
Compress/exp check
O/P image bus check
S800 error
S800 error
PCIe device check IRIS(0)
PCIe device check IRIS(1)
CPU board (CPUB)
L-82
Y119930-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303

Table of Contents