Olivetti d-Color MF4003 Service Manual page 490

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
(5)  4###
Error code
4103
After the main power switch is switched ON, HTTP communication is
attempted under the condition where HTTP communication is not
ready.
4106
When data is uploaded from main body to the web server, the
network connection is not enabled and main body cannot start
communication.
41FA
Control error
• MIO response timed out.
(6)  5###
Error code
5###
MIO detects error at file sending.
(7)  6###
Error code
6###
MIO detects error during a sending sequence.
(8)  7###
Error code
7000
Acquisition of the certificate used in product authentication from a
USB device or PSWC failed.
7.3.4  When connecting by Fax modem
Error code
T50
Host terminal ID not correct
R80
Serial number received from the host not correct.
R81
Disconnection of writing instruction from host during machine is
running.
R82
Disconnection of FAX-CSRC instruction when FAX-CSRC is not
allowed.
R83
Host command error.
R84
NVRAM writing error.
Service Manual
Contents
Contents
Contents
Contents
Contents
L-92
L TROUBLESHOOTING > 7. CS Remote Care ERROR CODE
Wait for a while and try transmitting again.
Wait for a while and try transmitting again.
Turn the main power switch OFF and then ON.
Check the http server environment.
Check the http server environment.
Acquire a new certificate (within 6 days after the
issue).
Check the telephone number set for host.
Check the status of the machine registration on host
side.
Wait for a while and try transmitting again.
Check the status of the machine registration on host
side.
Contact OLI and inform the error code.
Contact OLI and inform the error code.
Solution
Solution
Solution
Solution
Solution
Y119930-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303