d-Color MF4003/MF3303
Setting item
User Name
Set the user name used to access the WebDAV server.
Password
Set the password that is used to access the WebDAV server.
Port Number
Set the port number that is used to access the WebDAV server.
Proxy
Set whether or not to connect to a proxy server.
SSL Settings
Select to use SSL communication.
Log Save Destination
• Configures the server for storing files used for [Remote Log Retrieval].
• Touch [Copy Setting] after settings parameters are selected to copy the settings to the destination as configured from [Command Set
Acquisition Pt.].
Setting item
Host Name
Set the host name of the WebDAV server.
File Path
Set the file path used in the WebDAV server communication.
User Name
Set the user name used to access the WebDAV server.
Password
Set the password that is used to access the WebDAV server.
Port Number
Set the port number that is used to access the WebDAV server.
Proxy
Set whether or not to connect to a proxy server.
SSL Settings
Select to use SSL communication.
3.6  Enable Core Dump
To set whether to acquire a log of Core Dump.
Enable
Disable
NOTE
▪ When [Enable] is selected, select a saving location and press [Fix].
▪ When [Remote Log Server] is selected, be sure to complete setting of [Log Save Destination] in [Remote Log Server Settings].
3.7  USB Password
• To set a password used to store debug information into a USB flash drive.
• Default setting: 01234567890123456789
• CE informs the OLI contact person of this password and the debug information data separately.
NOTE
▪ NEVER forget the USB password.
<Procedure>
1. Current Password: Enter the USB password currently in use.
2. New Password: Enter a new USB password.
3. Re-input Password: Re-enter the new USB password.
3.8  Other
3.8.1  Screen Capture
• The screen displayed on the control panel can be captured and saved in a USB memory as a file.
NOTE
▪ Use a USB memory having no security functions.
▪ This setting is unavailable when [Administrator] -> [Security] -> [Security Details] -> [Export Debug Log] is set to "Restrict."
Preparations
1. Touch [Other].
2. Touch [Screen Capture] and then [END].
3. Insert the USB memory.
Capturing individually
1. Call the screen to be captured to the control panel.
Service Manual
Contents
Contents
Setting item
USB memory
Remote Log Server
J BILLING SETTING/ENHANCED SECURITY/DEBUG SETTINGS > 3. DEBUG
J-32
Setting value
64 characters maximum
64 characters maximum
1 - 65535
ON
OFF
ON
OFF
Setting value
Alphanumeric characters
and symbols up to 253
characters
142 characters maximum
64 characters maximum
64 characters maximum
1 - 65535
ON
OFF
ON
OFF
Default setting
Y119930-3
SETTINGS
Default
setting
-
-
80
Default
setting
-
-
-
-
80

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303

Table of Contents