d-Color MF4003/MF3303
Items
Line 1
20 pps pulse dial
000E00E6
make time
20 pps pulse dial
000E00E7
break time
20 pps pulse dial
000E00E8
inter-digit pause
PB signal
000E00E9
transmission level
PB signal level
000E00EA 000E01FA 000E030A 000E041A 7-0 PB signal level difference (H-
difference (H-L)
DC-LOOP
000E00EB 000E01FB 000E030B 000E041B 7-0 DC-LOOP integration time at
integration time at
CML OFF
DC-LOOP
000E00EC 000E01FC 000E030C 000E041C 7-0 DC-LOOP integration time at
integration time at
CML ON
Pause time
000E00ED 000E01FD 000E030D 000E041D 7-3 -
DC-LOOP check
000E00EE 000E01FE 000E030E 000E041E
mode
DC-LOOP waiting
000E00EF 000E01FF 000E030F
time
DC-LOOP
000E00F0
instantaneous
break allowable
time (ph.A)
DC-LOOP
000E00F1
instantaneous
break allowable
time (ph.B)
Dial mode RING
000E00F2
DET mode
Service Manual
Address
Line 2
Line 3
Line 4
000E01F6
000E0306
000E0416 7-0 20 pps pulse dial make time
000E01F7
000E0307
000E0417 7-0 20 pps pulse dial break time
000E01F8
000E0308
000E0418 7-0 20 pps pulse dial inter digit
000E01F9
000E0309
000E0419 7-0 PB signal transmission level
000E041F 7-0 DC-LOOP waiting time (unit:
000E0200
000E0310
000E0420 7-0 DC-LOOP instantaneous
000E0201
000E0311
000E0421 7-0 DC-LOOP instantaneous
000E0202
000E0312
000E0422
Data
Bit
Contents
pause (unit: 10 ms)
(unit: 1 dBm)
L) (unit: 0.5 dBm)
CML relay OFF (unit: 5 ms)
(Lower limit 20 ms)
CML relay ON (unit: 5 ms)
(Lower limit 20 ms)
2-0 Pause time (unit: sec.)
7
DC-LOOP check
0: No
1: Always
6-1 -
0
T81 line disconnection check
(T80 if line disconnected)
0: Yes
1: No
100 ms)
break allowable time (unit: 10
ms)
(at the time of calling, CML
ON to end of dialing)
break allowable time (unit: 10
ms)
(after completion of dialing
and after CML ON at the time
of reception)
7
Wrong dial determination
function
0: Disable
1: Enable
6
-
5-4 RING detection mode
01: No. of times
10: Time
3-2 Pulse format
00: General
01: SW
10: NO
1-0 Dialing method
00: PB
01: 10 pps
10: 20 pps
11: 16 pps
I-112
I SERVICE MODE > 16. FAX
Default
Setting
Data
01011110
(EU)
7 (JP)
00000111
9 (US/EU)
(JP)
00001001
(US/EU)
16 (JP)
00010000
14 (US/EU)
(JP)
00001110
(US/EU)
890 ms (JP)
01011001
640 ms (US)
(JP)
920 ms (EU)
01000000
(US)
01011100
(EU)
10 dBm (JP/US)
00001010
6 dBm (EU)
(JP/US)
00000110
(EU)
2 dBm
00000100
400 ms
01010000
80 ms
00010000
-
00000001
1 sec.
No
00000000
-
Yes
0 ms
00000000
0 ms
00000000
0 ms
00000000
Disable
00010010
(JP)
00010000
(US/EU)
-
No. of times
General
20 pps (JP)