Olivetti d-Color MF4003 Service Manual page 504

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
Error
Catego
Contents of error
code
ry
R02
Recepti
A DCN is received when
on
the remote station is
(Ph.B)
disconnected first due to
T1 timeout and etc.
R03
Protocol error (received
unexpected command
during DCS waiting)
R04
Unable to identify the
analysis result and the
communication mode of
the received DCS signal
R06
Recepti
An image data error in
on
all frames exceeds a
(Ph.D)
predetermined
frequency
R07
Recepti
Unable to detect image
on
data
(Ph.C)
Example: The fax
machine is
disconnected, or the
image data cannot be
identified due to a line
defect.
R08
Signal interrupted while
receiving image data
Example: The image
data terminal cannot be
detected and the post
message (PPS-EOP/
MPS/NULL) cannot be
detected.
R09
Recepti
Received the DCN when
on
waiting the post
(Ph.D)
message (PPSEOP/
MPS/NULL)
Example: The remote
station is disconnected
due to exceeded number
of times for
retransmission
(Also occurs after
returning the MCF/PPR)
Service Manual
How to correct
3. If the error occurs on the specific destination, ask it to
pay attention not to send fax with mixed-size original or
incorrect resolution. (Due to issues on remote station)
1. Change the lowest reception sensitivity to -43 dBm.
Change the signal transmission level to -15 dBm.
2. Extend the DIS retransmission interval.
* If no effect is obtained, return the setting.
1. Extend V.21 signals interval.
Increase by +20 ms.
* If no effect is obtained, return the setting.
2. Extend the DIS retransmission interval to 4.5 seconds.
* If no effect is obtained, return the setting.
It cannot be dissolved by settings, so acquire a log.
(since an error may occur on the DIS received from the
remote station or altered by exchangers in midway)
• Protocol trace list for errors (including remote station)
• Line information for both fax machine and remote
station
• Machine management list (CSV save), activity report
1. Change the lowest reception sensitivity to -43 dBm.
Change the signal transmission level to -15 dBm.
2. Set the reception beginning speed to V.29/V.27ter.
3. Possibility of line defect (example: echo, distortion)
1. Change the lowest reception sensitivity to -43 dBm.
Change the signal transmission level to -15 dBm.
2. Implement test on the CFR return timing with each value.
(80ms/100ms/120ms/140ms/160ms/180ms)
3. Set the reception beginning speed to V.29/V.27ter.
4. Connect the ground for the MFP or TA.
5. Possibility of line defect (example: echo, distortion)
1. Check the telephone line.
2. Check the possibility that the job may be deleted from
the fax machine.
3. Change the lowest reception sensitivity to -43 dBm.
Change the signal transmission level to -15 dBm.
4. Set the reception beginning speed to V.29/V.27ter.
5. Possibility of line defect (example: echo, distortion)
1. Change the lowest reception sensitivity to -43 dBm.
Change the signal transmission level to -15 dBm.
2. Possibility of line defect (example: packet loss, echo,
distortion)
L-106
L TROUBLESHOOTING > 9. FAX TROUBLE CODE
Installation position
(Service Mode -> [FAX] -> [Line #])
-
• [Modem/NCU] -> [Level] -> CD/
SED ON Level
• [Modem/NCU] -> [TxATT] -> PIX
TxATT, TONE/Procedure Signal
TxATT, CED/ANSam TxATT
[Function Parameter]: 000E0053 -> 4.5
sec (0x2D=00101101)
[Function Parameter]: 000E0060
(×1ms)
[Function Parameter]: 000E0053
4.5s=0x2D(00101101)
-
• [Modem/NCU] -> [Level] -> CD/
SED ON Level
• [Modem/NCU] -> [TxATT] -> PIX
TxATT, TONE/Procedure Signal
TxATT, CED/ANSam TxATT
[Modem/NCU] -> [V17 Send Max
Speed] -> RX Max. Speed
-
• [Modem/NCU] -> [Level] -> CD/
SED ON Level
• [Modem/NCU] -> [TxATT] -> PIX
TxATT, TONE/Procedure Signal
TxATT, CED/ANSam TxATT
[Function Parameter]: 000E005C
(×10ms)
[Modem/NCU] -> [V17 Send Max
Speed] -> RX Max. Speed
-
-
-
-
• [Modem/NCU] -> [Level] -> CD/
SED ON Level
• [Modem/NCU] -> [TxATT] -> PIX
TxATT, TONE/Procedure Signal
TxATT, CED/ANSam TxATT
[Modem/NCU] -> [V17 Send Max
Speed] -> RX Max. Speed
-
• [Modem/NCU] -> [Level] -> CD/
SED ON Level
• [Modem/NCU] -> [TxATT] -> PIX
TxATT, TONE/Procedure Signal
TxATT, CED/ANSam TxATT
-
Y119930-3

Hide quick links:

Advertisement

Table of Contents
loading