Olivetti d-Color MF4003 Service Manual page 215

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
1. Touch [Immediate Update] to start update.
2. Touch [Yes] on the confirmation screen, and touch [OK].
NOTE
▪ Do not set the power to OFF under the following state.
▪ It takes about 45 seconds from touching [Immediate Update] -> [Start] to the next operation of the MFP (Auto Power OFF).
▪ About one minute after the download completed screen being displayed, the MFP will restart.
▪ When rewriting configuration files followed by the firmware, the MFP will restart again.
(6)  Machine Update Password
• To set a password used to decrypt the configuration file(s) of the machine.
<Procedure>
• Enter the decryption password using the on-screen keyboard.
Setting item
Current Password
Enter the currently used decryption password (only when the decryption password has been set).
New Machine Update
Enter the new decryption password.
Password
Confirm Machine
Enter the new decryption password again.
Update Password
NOTE
▪ Once a password is set, be sure not to forget it. It is required for reset.
▪ Please refer to "
I.18.2.1 Auto Update
12.6.3  HTTP Proxy Settings
• To select whether to connect via a proxy server to access the http server.
• To configure the settings of the server related to connection via a proxy server.
ON
OFF
<Procedure>
• If [ON] is selected, configure the following settings.
1. Touch [Host Address] in [Proxy Server Address] to set the host address of the proxy server.
2. Set the port number used to access the proxy server in [Proxy Server Port Number].
3. Select whether to perform an authentication to access a proxy server. If [ON] is set, enter the user name and password.
12.7  Storage Management
12.7.1  Encrypt Settings
• To set a password used to encrypt data when storing it into the MFP storage.
• Default setting: 01234567890123456789
<Procedure>
1. Enter the encryption passphrase currently in use.
2. Encryption Passphrase: Enter a new encryption passphrase.
3. Encryption Passphrase Confirmation: Re-enter the new encryption passphrase.
12.7.2  Debug Log Encryption Settings
• To set a password used to encrypt debug data when storing it into the HDD.
• Default setting: 01234567890123456789
<Procedure>
1. Enter the encryption passphrase currently in use.
2. Encryption Passphrase: Enter a new encryption passphrase.
3. Encryption Passphrase Confirmation: Re-enter the new encryption passphrase.
Y119930-3
setting" for how to make the configuration file(s).
Setting item
H UTILITY MODE > 12. Supplementary explanation of utility mode