d-Color MF4003/MF3303
Signal Definition
Signal type
CI (Call Indicator)
Function display on
the calling side
[Comments]
• CI is a signal to carry call function.
• The calling side send CI, CT (Call Tone - V25) or CNG.
• CI transmission and detection are optional.
• The ON minimum time (=3 Period) is of duration of three CI signals in the following format.
ANSam (Modified
V.8 procedure on
Answer Tone)
the called side
Support display
[Comments]
• Essential for a called machine which supports the V8 procedure.
• 2100 Hz sine wave is phase-inverted by 400 +/-25 ms periods, then amplitude modulated by 15 +/-0.1 Hz sine
• Average value of modulation factor (x) 0.8 +/- 0.01 < x < 1.2 +/- 0.01
• Average transmission power compliant to V2
• 2100 +/- 200 Hz external power is smaller than the average power by 24 dB or more.
CM (Call Menu)
Modulation mode
etc. on the calling
side
[Comments]
• CM is a signal which carries call function, modulation modes, protocols and GSTN access.
• The first information category is call function.
• Protocols and GSTN access category are added when the calling side has ability and when needed to inform to
CJ
CM termination
[Comments]
• START bit (0) and STOP bit (1) are added to 1 octet of all bit 0.
• Signal format
JM (Joint Menu)
Display of common
ability on both
calling and called
sides
[Comments]
• JM is a response signal to CM and of the same format as the received CM.
• The fist information category is Call Function as same as CM.
• Modulation mode sets the common bit on calling and called sides and sends by the same octet as received CM.
• When there is no common ability, all bits are set to 0 and send by the same octet as received CM.
• The minimum item No. is selected from the common bits to determine the actual Modulation Mode.
• Protocol is added when it is included in received CM and needed to instruct.
• GSTN access is added when it is included in received CM and needed to instruct.
• Bit 6 is set to ON when needed to show ability. Bit 5 is set to the same one as received CM.
Signal format
1. Preamble: a signal added before each signal when CI, CM and JM signals are sent.
• Format: 1111111111 +0000000001 (for CI)
• Format: 1111111111 +0000001111 (for CM and JM)
2. Common format among each signal CI, CM and JM
• Start Bit (=0) is put at the top and Stop Bit (=1) is put at the end of each octet.
Service Manual
Meaning
Signal direction
Call Called
->
<-
wave
->
(300 bps)
a remote station.
->
(300 bps)
Start bit
b0
b1
0
0
0
<-
(300 bps)
Signal
speed
V.21 (L)
• Start: after 0.4 seconds after line connection from ON
(300 bps)
condition (in the following format)
• Stop: when 3 period or more has passed after ANSam/
ANS is detected
ON
-
When 0.2 seconds or more has passed after reception
V.21 (L)
• Start: Te (0.5 sec. ≤ Te ≤ 1 sec.) has passed after CI
transmission stops
• Stop: When two or more JM are detected
V.21 (L)
When CM is completed
Stop bit
b2
b3
b4
b5
b6
b7
0
0
0
0
0
0
1
V.21 (H)
• Start: When two or more same CM are received
• Stop: When CJ is received or receives a signal matching
the selected Modulation Mode from the calling side
P-96
P THEORY OF OPERATION > 8. FK-517
Timing of transmission
ON: 3period< T < 2sec
OFF
OFF: 0.4sec < T < 2sec
Y119930-3