Olivetti d-Color MF4003 Service Manual page 469

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
Trouble detection condition The file or data that is necessary to start the virus scan has been lost.
Trouble isolation
-
Relevant electrical parts
Storage board (STRGB)
Procedure
1. Reboot the machine. (MFP will reboot maximum 2 times by itself.)
2.
Replace STRGB.
3.19.5  CE101
Contents
Trouble type
CE101: Browser finish detected
Rank
C
Trouble detection condition
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check the connectors on BASEB for proper connection and correct as necessary.
2.
Replace CPUB.
3.
Replace BASEB.
3.19.6  CE201
Contents
Trouble type
CE201: Transmission operation log storage fault
Rank
C
Trouble detection condition When the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is
detected when the retrial failed for predetermined number of times.
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check the connectors on BASEB for proper connection and correct as necessary.
2.
Replace CPUB.
3.
Replace BASEB.
3.19.7  CE202
Contents
Trouble type
CE202: PDL interpreter error
Rank
C
Trouble detection condition An error inside the CPU board (CPUB) is detected during converting the PDL information.
Trouble isolation
-
Relevant electrical parts
Procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] -> [Logical Format] and perform the function.
3. Select [System 1] -> [Initialization] -> [Clear All Data] and perform the function.
4.
Replace CPUB.
5.
Replace BASEB.
3.19.8  CE203
Contents
Trouble type
CE203: Unrecoverable error
Rank
C
Trouble detection condition An error does not recover even after an auto recovery.
Trouble isolation
-
Relevant electrical parts
Y119930-3
• The browser is automatically recovered (restarted) after the main body detected that the browser (separate
process) has stopped with fault.
• When the "Malfunction finish is detected over predetermined number of times" or "the browser task process is
except in idle (printing, etc.)".
• CPU board (CPUB)
• Base board (BASEB)
• CPU board (CPUB)
• Base board (BASEB)
• CPU board (CPUB)
• Base board (BASEB)
• CPU board (CPUB)
• Base board (BASEB)
L TROUBLESHOOTING > 3. TROUBLE CODE
L-71
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303

Table of Contents