Olivetti d-Color MF4003 Service Manual page 438

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
3.
Replace the PH unit.
4.
Replace CPUB.
5.
Replace BASEB.
3.11  C5###
3.11.1  C5102, C5103
Contents
Trouble type
Rank
B
Trouble detection condition
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check the connector between M1-BASEB CN17E for proper connection and correct as necessary.
2. Check the loading status of the main drive, and correct the error as necessary.
3. Check CPUB for proper installation and correct as necessary.
4. M1 load check
• Check code: 40
• Multi code: 1, 2
• Control signal: BASEB CN17E-1 to 5
• Location of electrical component: 1-C
5.
Replace M1.
6.
Replace CPUB.
7. BASEB F18E conduction check
8.
Replace BASEB.
3.11.2  C5357
Contents
Trouble type
C5357: Machine cooling fan failure to turn
Rank
B
Trouble detection condition The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check the connector between FM1-relay CN23-BASEB CN19E for proper connection and correct as necessary.
2. Check the fan for possible overload and correct as necessary.
3. Check CPUB for proper installation and correct as necessary.
4. FM1 load check
• Check code: 42
• Multi code: 1, 2
• Control signal: BASEB CN19E-4 (REM), BASEB CN19E-6 (LOCK)
• Location of electrical component: 9-C
5.
Replace FM1.
6.
Replace CPUB.
7.
Replace BASEB.
3.11.3  C5360
Contents
Trouble type
C5360: Clean unit fan failure to turn (When CU-202 is installed) (Europe models only)
Rank
B
Trouble detection condition The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check the connector between CUDB CN1-relay CN35-BASEB CN25E for proper connection and correct as necessary.
Service Manual
• C5102: Main motor failure to turn
• C5103: Main motor turning at abnormal timing
• C5102: The control circuit detects motor failure to turn while the motor is turning.
• C5103: The control circuit detects motor turning while the motor remains stationary.
• Main motor (M1)
• CPU board (CPUB)
• Base board (BASEB)
• Machine cooling fan (FM1)
• CPU board (CPUB)
• Base board (BASEB)
• Exhaust fan/1 (FM1)
• Exhaust fan/2 (FM2)
• Exhaust fan/3 (FM3)
• Clean unit drive board (CUDB)
• CPU board (CPUB)
• Base board (BASEB)
L TROUBLESHOOTING > 3. TROUBLE CODE
L-40
Y119930-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303

Table of Contents