Rep 10.9 Fuser Connector/Harness (4265) - Xerox WorkCentre 4150 Service Manual

Hide thumbs Also See for WorkCentre 4150:
Table of Contents

Advertisement

REP 10.9 Fuser Connector/Harness (4265)

Parts List on
PL 10.28
Removal
NOTE: This procedure should only be performed on the 4265. For the 4150/4250/4260
machines, refer to the Table of Contents.
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions,
1.
Power off the machine. Disconnect the power cord.
2.
Remove the Exit Guide Assembly
(REP
3.
Remove the Fuser Assembly
(REP
Repairs and Adjustments
REP 10.9
WARNING
WARNING
CAUTION
GP
10.2).
10.1).
4.
Detach the Fuser Connector Cover from the frame
2
Detach the Connector Cover.
10.
Figure 1 Detaching the Connector Cover from the Frame
January 2016
4-162
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
(Figure
1).
1
Remove the two mounting screws.