04-910 SMPS Fan Locked RAP
04-910 The machine has detected a fault with the SMPS fan.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Go to the relevant procedure:
4150 Checkout
4250/4260 Checkout
4265 Checkout
4150 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the
PWB
PJ location illustration.
Refer to
Wiring Diagram
1. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Enter
dC330
code 09-500 and 09-510. Check that the SMPS fan,
normal speed.
3.
Check the wiring between the SMPS fan and CON2 on
4.
Install new components as necessary:
SMPS fan,
PL 4.15 Item
18.
Power supply unit 2,
PL 1.10 Item
4250/4260 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the
PWB
PJ location illustration.
Refer to
Wiring Diagram
21. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Enter
dC330
code 09-500 and 09-510. Check that the SMPS fan,
normal speed.
3.
Check the wiring between the SMPS fan and CN5 on the
4.
If necessary, install a new SMPS fan,
5.
Perform the
OF5
Main PWB Check RAP.
4265 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the
PWB
PJ location illustration.
Refer to
Wiring Diagram
37. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Enter
dC330
code 09-500 and 09-510. Check that the SMPS fan,
normal speed.
3.
Check the wiring between the SMPS fan and CN14 on the
4.
If necessary, install a new SMPS fan,
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
WARNING
PL 4.15 Item 18
Power Supply Unit
2.
4.
PL 4.15 Item 18
Main
PWB.
PL 4.15 Item
18.
PL 4.15 Item 18
Main
PWB.
PL 4.15 Item
18.
5.
Perform the
OF5
Main PWB Check RAP.