WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
03-910 MCB to NIC Communications Fault RAP
03-910 A main PWB to NIC PWB communications error has been detected.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Refer to
Wiring Diagram
6. Perform the following:
NOTE: The network connection has two LEDs The green LED on indicates that the network
connection is ready. The amber LED flashing indicates that the network is good.
1.
Switch off the machine, then switch on the machine.
2.
Make sure that the network cable is connected to the machine.
3.
Make sure that the NIC PWB,
4.
Go to
GP 4
System Administration Tools. Check with the customer that the connectivity
and network setup settings are correct.
5.
If necessary, install a new NIC PWB,
6.
Perform the
OF5
Main PWB Check RAP.
January 2016
2-19
WARNING
PL 1.10 Item 13
is securely installed on to the main PWB.
PL 1.10 Item
13.