REP 10.8 Fuser Connector (4250/4260)

Parts List on
PL 4.15
Removal
NOTE: This procedure should only be performed on the 4250/4260. For the 4150 or 4265 pro-
cedure, refer to the table of contents.
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions,
1.
Remove the exit guide assembly,
REP
2.
Remove the fuser assembly,
REP
10.1.
3.
Prepare to remove the fuser connector,
Figure 1 preparation
WorkCentre 4150/4250/4260WorkCentre WorkCentre 4150/4250/42604150/
WARNING
WARNING
CAUTION
GP
10.2.
Figure
1.
1
Remove 2 screws.
3
Lift the fuser
connector cover.
2
Disconnect CON4 from power
supply unit 2.
4.
Remove the fuser connector,
10.
Replacement
Replacement is the reverse of the removal procedure.
January 2016
4-161
Figure
2.
1
Remove 2 screws, then the
fuser connector from the cover.
1
Disconnect the white connector.
Figure 2 Fuser connector