5.
Remove the Lower Exit Frame
(Figure
1
Remove the four
mounting screws.
2
Remove the Lower
Exit Frame.
Figure 2 Removing the Lower Exit Frame
Repairs and Adjustments
REP 5.22
2).
6.
Remove the DADF Exit Sensor
2
Remove the DADF Exit Sensor.
1
Disconnect the connector.
Figure 3 Removing the DADF Exit Sensor
Replacement
1.
Reinstallation is the reverse of the Removal procedure.
January 2016
4-84
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
(Figure