IQ16 Horizontal Bands RAP

Use this RAP when the image has bands appearing across the process direction. An example
is shown in
Figure
1.
Figure 1 Horizontal bands
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Perform the following:
1.
Check the spring contacts in the terminal assembly,
supply the voltages to the xerographic module and the side cover assembly. If necessary,
clean the spring contacts. If necessary, install a new terminal assembly,
2.
Make 10 blank copies to clean the xerographic drum. If necessary, install a new xero-
graphic module,
PL 9.10 Item
1.
3.
Measure the distance between the image and the defect. Refer to
2
(4250/4260) to determine the possible cause of the defect.
Table 1 Defect distance (4150)
Defect distance
Roller
94mm (3.7 inches)
Xerographic drum
38mm (1.5 inches)
Charge roller
44mm (1.7 inches)
Supply roller
57mm (2.2 inches)
Transfer roller
126mm (4.9 inches)
Heat roller
155mm (6.1 inches)
Pressure roller
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
WARNING
PL 4.15 Item
13. The spring contacts
PL 4.15 Item
Table 1
(4150) or
Component
Parts List Ref.
Xerographic module
PL 9.10 Item 1
Xerographic module
PL 9.10 Item 1
Xerographic module
PL 9.10 Item 1
Transfer roller
PL 7.35 Item 19
Fuser assembly
PL 10.26 Item 13
Fuser assembly
PL 10.26 Item 23
Table 2 Defect distance (4250/4260)
Defect distance
Roller
94mm (3.7 inches)
Xerographic drum
38mm (1.5 inches)
Charge roller
44mm (1.7 inches)
Supply roller
57mm (2.2 inches)
Transfer roller
126mm (4.9 inches)
Heat roller
155mm (6.1 inches)
Pressure roller
4.
Install new components as necessary.
5.
(4150) Check the condition of the fuser assembly. Install new components as necessary,
PL 10.25
and
PL
10.26.
6.
(4250/4260) Check the condition of the fuser assembly. Install new components as nec-
essary,
PL 10.28
and
PL
7.
(4265) Check the condition of the fuser assembly. Install new components as necessary,
PL 10.28
and
PL
10.30.
8.
Perform the
OF5
Main PWB Check RAP.
13.
Table
January 2016
3-19
Component
Xerographic module
Xerographic module
Xerographic module
Transfer roller
Fuser assembly
Fuser assembly
10.30.
Parts List Ref.
PL 9.10 Item 1
PL 9.10 Item 1
PL 9.10 Item 1
PL 7.35 Item 19
PL 10.30 Item 10
PL 10.30 Item 31