Code
Parameter
O1
Output frequency
O2
Freq. reference
O3
Motor speed
O4
Motor current
O5
Motor torque
O6
Motor power
O7
Motor voltage
O8
DC-link voltage
O9
Unit temperature
O10
Motor temperature
Keypad reference
R11
b
PI keypad setpoint 1
R12
b
Parameter value will be set to be default when changing macros.
b
Table 9. Parameters (Cont.).
.
P1 - Basic
parameters.
Minimum frequency
P1.1
b
0.00 Hz
Minimum value:
Description:
Defines the lowest frequency at which the drive will operate. This setting will limit other frequency parameter settings.
1 = Fire mode minimum frequency.
2 = Derag.
3 = MPFC staging frequency.
4 = MPFC master fixed frequency.
5 = Prime pump frequency.
6 = Prime pump frequency 2.
Maximum frequency
b
P1.2
Minimum value:
0.00 Hz
Description:
Defines the highest frequency at which the drive will operate. This will limit other frequency parameters.
1 = Keypad reference.
3 = Motor potentiometer.
3 = Jog speed.
4 = 2nd stage ramp frequency.
5 = Fire mode minimum frequency.
6 = Derag.
7 = MPFC staging frequency.
8 = MPFC master fixed frequency.
9 = Prime pump frequency.
10 = Prime pump frequency 2.
11 = Preset speed frequency.
12 = Frequency limit value.
13 = Reference limit value.
14 = Speed control_fs2.
15 = Stall frequency limit.
16 = 4 mA fault frequency.
17 = MPFC de-staging frequency.
18 = Pipe fill loss frequency low.
19 = Pipe fill loss frequency high.
20 = Broken pipe frequency limit.
Accel. time 1
P1.3
b
Minimum value:
0.1 s
Description:
Defines the time required for the output frequency to accelerate from zero frequency to maximum frequency.
POWERXL DM1 SERIES VARIABLE FREQUENCY DRIVES MN040049EN—September 2021 www.eaton.com
Min.
Max.
Unit
Hz
Hz
rpm
A
%
%
V
V
ºC
%
Hz
Minimum
Maximum
frequency
frequency
Varies
PI process
PI process
minimum
maximum
Maximum value:
Maximum value:
Maximum value:
Default
ID
1
24
2
3
4
5
6
7
8
9
0.00
141
0.00
1307
400.00 Hz
Default value:
400.00 Hz
Default value:
3,000.0 s
Default value:
Chapter 4 - Standard
Note
ID 101
0.00 Hz
ID 102
MaxFreqMFG
ID 103
20.0 s
21