Instruction Leaflet PUB53675
PowerXL DM1 and DM1 Pro series VFD
(Original instructions)
Instruction Leaflet
Montageanweisung
Notice d'installation
Instrucciones de montaje
Istruzioni per il montaggio
安 安 装 装 说 说 明 明
Инструкция по монтажу
Electric current! Danger to life!
en
Only skilled or instructed persons may
carry out the following operations.
Lebensgefahr durch elektrischen Strom!
de
Nur Elektrofachkräfte und elektrotechnisch
unterwiesene Personen dürfen die im Folgenden
beschriebenen Arbeiten ausführen.
Tension électrique dangereuse !
fr
Seules les personnes qualifiées et averties doivent
exécuter les travaux ci-après.
¡Corriente eléctrica! ¡Peligro de muerte!
es
El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.
Tensione elettrica: Pericolo di morte!
it
Solo persone abilitate e qualificate possono eseguire
le operazioni di seguito riportate.
zh
触 触 电 电 危 危 险 险 ! !
只允许专业人员和受过专业训练的人员进行下列工作。
Электрический ток! Опасно для жизни!
ru
Только специалисты или проинструктированные
лица могут выполнять следующие операции.
Levensgevaar door elektrische stroom!
nl
Uitsluitend deskundigen in elektriciteit en
elektrotechnisch geïnstrueerde personen is het
toegestaan, de navolgend beschreven
werkzaamheden uit te voeren.
Livsfare på grund af elektrisk strøm!
da
Kun uddannede el-installatører og personer der
e instruerede i elektrotekniske arbejdsopgaver,
må udføre de nedenfor anførte arbejder.
Προσοχή, κίνδυνος ηλεκτροπληξίας!
el
Οι εργασίες που αναφέρονται στη συνέχεια θα
πρέπει να εκτελούνται μόνο από ηλεκτρολόγους
και ηλεκτροτεχνίτες.
Montagehandleiding
Montagevejledning
Οδηγίες εγκατάστασης
Instruções de montagem
Monteringsanvisning
Asennusohje
Návod k montáži
Perigo de vida devido a corrente eléctrica!
pt
Apenas electricistas e pessoas com formação
electrotécnica podem executar os trabalhos
que a seguir se descrevem.
Livsfara genom elektrisk ström!
sv
Endast utbildade elektriker och personer som
undervisats i elektroteknik får utföra de arbeten
som beskrivs nedan.
Hengenvaarallinen jännite!
fi
Vain pätevät sähköasentajat ja opastusta saaneet
henkilöt saavat suorittaa seuraavat työt.
Nebezpečí úrazu elektrickým proudem!
cs
Níže uvedené práce smějí provádět pouze
osoby s elektrotechnickým vzděláním.
Eluohtlik! Elektrilöögioht!
et
Järgnevalt kirjeldatud töid tohib teostada ainult
elektriala spetsialist vői elektrotehnilise
instrueerimise läbinud personal.
Életveszély az elektromos áram révén!
hu
Csak elektromos szakemberek és
elektrotechnikában képzett személyek
végezhetik el a következőkben leírt munkákat.
Elektriskā strāva apdraud dzīvību!
lv
Tālāk aprakstītos darbus drīkst veikt tikai
elektrospeciālisti un darbam ar elektrotehniskām
iekārtām instruētās personas!
Pavojus gyvybei dėl elektros srovės!
lt
Tik elektrikai ir elektrotechnikos specialistai gali
atlikti žemiau aprašytus darbus.
Porażenie prądem elektrycznym stanowi
pl
zagrożenie dla życia!
Opisane poniżej prace mogą przeprowadzać tylko
wykwalifikowani elektrycy oraz osoby odpowiednio
poinstruowane w zakresie elektrotechniki.
Effective December 2021
Supersedes November 2021
Paigaldusjuhend
Szerelési utasítás
Montāžas instrukcija
Montavimo instrukcija
Instrukcja montażu
Navodila za montažo
Návod na montáž
sl
Spodaj opisana dela smejo izvajati samo
elektrostrokovnjaki in elektrotehnično
poučene osebe.
sk
Práce, ktoré sú nižšie opísané, smú vykonávat' iba
elektroodborníci a osoby s elektrotechnickým
vzdelaním.
bg
Операциите, описани в следващите раздели,
могат да се извършват само от
специалисти-електротехници и инструктиран
електротехнически персонал.
ro
Toate lucrările descrise trebuie efectuate numai
de personal de specialitate calificat şi de persoane
cu cunoştiinţe profunde în electrotehnică.
hr
Radove opisane u nastavku smiju obavljati samo
stručni električari i osobe koje su prošle
elektrotehničku obuku.
tr
Aşağdaki işlemleri yalnzca kalifiye veya eğitimli
kişiler gerçekleştirebilir.
uk
Виконувати означені далі операції дозволяється
тільки кваліфікованим особам, що пройшли
інструктаж.
ar
Eaton.com/EcoDesign-VFD
MZ040046EN
Монтажни инструкции
Instrucţiuni de montaj
Upute za montažu
Montaj talimat
Інструкція з монтажу
‫ﻣ ﻣ ﻨ ﻨ ﺸ ﺸ ـ ـ ـ ـ ـ ـ ـ ـ ـ ـ ﻮ ﻮ ر ر ا ا ﻟ ﻟ ﺘ ﺘ ﻌ ﻌ ﻠ ﻠ ﻴ ﻴ ﻤ ﻤ ـ ـ ـ ـ ـ ـ ـ ـ ـ ـ ﺎ ﺎ ت ت‬
Življenjska nevarnost zaradi
električnega toka!
Nebezpečenstvo ohrozenia života
elektrickým prúdom!
Опасност за живота от електрически ток!
Atenţie! Pericol electric!
Opasnost po život uslijed električne struje!
Elektrik akm! Hayati tehlike!
Електричний струм! Небезпечно для життя!
‫! ! ﺗ ﺗ ﺤ ﺤ ـ ـ ـ ـ ﺬ ﺬ ﻳ ﻳ ﺮ ﺮ ! ! ﺗ ﺗ ﻴ ﻴ ـ ـ ـ ـ ﺎ ﺎ ر ر ﻛ ﻛ ﻬ ﻬ ﺮ ﺮ ﺑ ﺑ ـ ـ ـ ـ ﺎ ﺎ ﺋ ﺋ ﻲ ﻲ ! ! ﺧ ﺧ ﻄ ﻄ ـ ـ ـ ـ ﺮ ﺮ ﻣ ﻣ ـ ـ ـ ـ ﻮ ﻮ ت ت‬
‫ﻻ ﺗﺘـــــﻢ اﻋﻤـــــﺎل اﻟﺼـــــﻴﺎﻧﺔ و اﻟﺘﺮﻛﻴـــــﺐ‬
‫! اﻻ ﻣــــﻦ ﻗﺒــــﻞ اﻟﻌــــﺎﻣﻠﻴﻦ اﻟﻤــــﺪرﺑﻴﻦ‬
! !

Advertisement

Table of Contents
loading

Summary of Contents for Eaton PowerXL DM1 Series

  • Page 1 Opisane poniżej prace mogą przeprowadzać tylko ‫ﻻ ﺗﺘـــــﻢ اﻋﻤـــــﺎل اﻟﺼـــــﻴﺎﻧﺔ و اﻟﺘﺮﻛﻴـــــﺐ‬ Οι εργασίες που αναφέρονται στη συνέχεια θα wykwalifikowani elektrycy oraz osoby odpowiednio ‫! اﻻ ﻣــــﻦ ﻗﺒــــﻞ اﻟﻌــــﺎﻣﻠﻴﻦ اﻟﻤــــﺪرﺑﻴﻦ‬ πρέπει να εκτελούνται μόνο από ηλεκτρολόγους poinstruowane w zakresie elektrotechniki. και ηλεκτροτεχνίτες. Eaton.com/EcoDesign-VFD MZ040046EN...
  • Page 2: Catalog Numbering System

    Shading legend DM1 option cards list: 1) DXM-NET-PROFIBUS : DM1 PROFIBUS communications card 2) DXM-NET-CANOPEN : DM1 CANOPEN communication card 3) DXG-NET-SWD-IP20 DG1: Smartwire communication card and module IP20 4) DXG-NET-SWD-IP54 DG1 : Smartwire communication card and module IP54 EATON www.eaton.com...
  • Page 3 DM1-32032… 32.2 48.3 7.68 (195) 11.81 (300) 11.06 (281) 7.24 (184) 6.3 (160) 6.3 (160) 0.24 (6) 13.9 (6.3) DM1-32048… 48.3 62.1 7.68 (195) 11.81 (300) 11.06 (281) 7.24 (184) 6.3 (160) 6.3 (160) 0.24 (6) 13.9 (6.3) EATON www.eaton.com...
  • Page 4 8.2 (3.7) DM1-35018… 18 7.68 (195) 11.81 (300) 11.06 (281) 7.24 (184) 6.3 (160) 6.3 (160) 0.24 (6) 13.9 (6.3) DM1-35022… 22 7.68 (195) 11.81 (300) 11.06 (281) 7.24 (184) 6.3 (160) 6.3 (160) 0.24 (6) 13.9 (6.3) EATON www.eaton.com...
  • Page 5 48.3 1.97 (50) 1.97 (50) 75.56 (128.4) DM1-32048… 48.3 62.1 1.97 (50) 1.97 (50) 75.56 (128.4) Note: For DM1 drives with an option card, allow 2.76 in. or 70 mm for dimension A for the option card enclosure. EATON www.eaton.com...
  • Page 6 58.61 (99.6) DM1-35018… 1.97 (50) 1.97 (50) 57.56 (97.8) DM1-35022… 1.97 (50) 1.97 (50) 57.56 (97.8) Note: For DM1 drives with an option card, allow 2.76 in. or 70 mm for dimension A for the option card enclosure. EATON www.eaton.com...
  • Page 7: Fr1 Mounting Instructions

    Two M5x20 or 3/16 inch screws Two M5 or 3/16 inch nuts Torque: 3 N.m (26.6 lb/in.) Max. distance: 100 mm (3.94 in.) Output magnetic core Input magnetic core Output grounding wire Input grounding wire 3 motor wires 3 line wires Screw mounting EATON www.eaton.com...
  • Page 8: Fr2 Mounting Instructions

    Four M5x20 or 3/16 inch screws Four M5 or 3/16 inch nuts Torque: 3 N.m (26.6 lb/in.) Max. distance: 100 mm (3.94 in.) Output magnetic core Input magnetic core Output grounding wire Input grounding wire Screw mounting 3 motor wires 3 line wires EATON www.eaton.com...
  • Page 9: Fr3 Mounting Instructions

    The input magnetic core and output magnetic core are the same for 3-phase FR3 EMI version. Max. distance: 100 mm (3.94 in.) Screw mounting Output magnetic core Input magnetic core Output grounding wire Input grounding wire 3 motor wires 3 line wires EATON www.eaton.com...
  • Page 10: Fr4 Mounting Instructions

    Use a cable tie to tie the input magnetic cores to the input wires. The output wires (only 3 motor wires) should run through the output magnetic core before connecting to output terminal block. EATON www.eaton.com...
  • Page 11 Clamp the cable with the optional card port. Mount the option card to the drive by inserting the four snaps into the slots on drive. Open type Step 2. Remove the option card port label and four snap covers from the drive. EATON www.eaton.com...
  • Page 12 No Use CAN_H Shield CANOpen card User terminal Grounding terminal User terminals (DB9 connector) 5. DGND 9. No Use 4. RTS 8. RXD/TXD-N Profibus card 7. No Use 2. No Use 6. VP 1. No Use Grounding terminal EATON www.eaton.com...
  • Page 13: Ground Wiring

    Ground wiring Removable MOV screw EMC screw Motor grounding position Line grounding position (FR1-FR2) M3, 7 in-lb (0.8 N · m) Line grounding wire Motor grounding wire (FR3-FR4) M4, 14 in-lb (1.6 N · m) Line wires Motor wires EATON www.eaton.com...
  • Page 14: Input Power And Motor Cable Stripping Lengths

    28-16 (0.5-1.5) 1.73 (0.2) 4.5 (0.5) DM1-32032… 32.2 48.3  4 (25) 33 (3.73)  8 (16) 14.2 (1.6) 28-16 (0.5-1.5) 1.73 (0.2) 4.5 (0.5) DM1-32048… 48.3 62.1  3 (35) 33 (3.73)  6 (16) 14.2 (1.6) 28-16 (0.5-1.5) 1.73 (0.2) 4.5 (0.5) EATON www.eaton.com...
  • Page 15 14.2 (1.6) 28-16 (0.5-1.5) 1.73 (0.2) 4.5 (0.5) Notes:  Strip the motor and power cables as shown above. ‚ Both UL and IEC tools may be used. ® ƒ Applies to strained wire, solid wire, or ferrule installations. EATON www.eaton.com...
  • Page 16 ‚ Earthing conductor size is determined by the maximum overcurrent device rating used ahead of the drive according to UL 508C Table 6.4. ƒ If power cubes or bypass are used, a UL listed Class RK5, J, T or equivalent fuse is recommended. EATON www.eaton.com...
  • Page 17 ‚ Earthing conductor size is determined by the cross-sectional area of phase conductors according to IEC/EN 61800-5-1:2007 Table 5. So if phase conductor size is changed, earthing conductor size should also be changed accordingly. ƒ If power cubes or bypass are used, a Class gG/gL fuse is recommended. EATON www.eaton.com...
  • Page 18 Instruction Leaflet PUB53675 PowerXL DM1 and DM1 Pro series VFD Effective December 2021 Installation overview for DM1 L1, L2, L3, R+, R-, U, V, W DM1/DM1 EATON www.eaton.com...
  • Page 19: Control Board Layout

    DM1 face plate DIP switches RJ45 port for Keypad/PC Relay terminals IO terminals Relay terminals I/O terminals Removable MOV screw EMC screw Line grounding position Motor grounding position Line grounding wire Motor grounding wire Motor wires Line wires EATON www.eaton.com...
  • Page 20: Factory-Set Control Terminal Functions

    24 V 24 Vdc control output 24 Vdc In/Out Control voltage input/output (100 mA max.). R1NO Relay 1 normally open Changes state when the drive is in the run state. R1CM Relay 1 common R1NC Relay 1 normally closed EATON www.eaton.com...
  • Page 21 The above wiring demonstrates a SINK configuration. The SW2 position 1 is set to ON. If a SOURCE configuration is desired, wire 24 V to CMA and close the inputs to ground. When using the +10 V for AI1, SW2 position 2 set to ON.  AI1+ support 10 K potentiometer. EATON www.eaton.com...
  • Page 22 že stroj splňuje požadavky ochrany stanovené směrnicí 2006/42/ES o strojních zařízeních. Nástavba odpovídající směrnici EMC. Řídicí a sít’ová vedení pokládejte prostorově oddělená od vedení motoru.  Stínění vedení spojte velkoplošně s PE. EATON www.eaton.com...
  • Page 23: Ul Cautions, Warnings, And Instructions

    Website www.eaton.com/drives www.eaton.com/AfterSales www.eaton.com.cn/electrical Email VFDaftermarketEG@eaton.com AfterSalesEGBonn@eaton.com CustomerServicePDCNA@eaton.com Phone 1-877-386-2273 (8:00 a.m. to 6:00 p.m. +49 (0) 180 5 223822 800 9881203 Eastern Time U. S. [UTC–5]) 800-543-7038 (6:00 p.m. to 8:00 a.m. Eastern Time U.S. [UTC–5]) TRCDrivesTechSupport@eaton.com EATON www.eaton.com...
  • Page 24 By separating waste electrical and electronic equipment , you will help reduce the volume of waste sent for incinera- Eaton.com/recycling tion or land-fills and minimize any potential negative impact on human health and environment. EATON www.eaton.com...
  • Page 25 Instruction Leaflet PowerXL DM1 and DM1 Pro series VFD PUB53675 Effective December 2021 EATON www.eaton.com...
  • Page 26 Instruction Leaflet PUB53675 PowerXL DM1 and DM1 Pro series VFD Effective December 2021 EATON www.eaton.com...
  • Page 27 Instruction Leaflet PowerXL DM1 and DM1 Pro series VFD PUB53675 Effective December 2021 PowerXL DM1 STO TUV Certificate RL (EC Type) EATON www.eaton.com...
  • Page 28 Instruction Leaflet PUB53675 PowerXL DM1 and DM1 Pro series VFD Effective December 2021 EATON www.eaton.com...
  • Page 29 Instruction Leaflet PowerXL DM1 and DM1 Pro series VFD PUB53675 Effective December 2021 EATON www.eaton.com...
  • Page 30 THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss...