Problems With the NiCad Battery Pack (continued)
The next table lists problems you may have with the NiCad battery pack while operating the reader.
Problem
When you press
to turn on the reader,
nothing happens or the reader
immediately turns itself off.
The Battery icon appears at the top of the
reader display.
You see all these symptoms:
The Battery icon remains on.
• The reader chirps every 5 seconds for
1 minute and then turns off.
• The reader sounds a double-beep
when you enter or scan data, and
sounds a double-click when you press
any key.
NF
Solution
Make sure the NiCad battery pack is installed correctly. Push
firmly on the bottom of the pack to lock it into the handle.
The NiCad battery pack may be discharged. Replace the battery
pack with a spare charged battery pack, or charge the battery
pack and try again.
The reader displays the Battery icon when the NiCad battery
pack has approximately 15 to 45 minutes of power left. If you
are using a J2020, replace the battery pack soon.
If you are using a JR2020, you should immediately replace or
recharge the battery pack because you will soon lose RF
communications.
Caution
When the Battery icon appears, save your data and
replace the battery pack as soon as possible.
Conseil
Quand l'icône de la pile apparaît, enregistrez vos données
et remplacez le jeu de piles aussitôt que possible, sinon
vous pourriez perdre des données.
The NiCad battery pack charge is critically low.
Save your data. Replace the battery pack with a spare charged
battery pack, charge the battery pack, or attach an external
power supply.
The laser scanner and RF communications are turned off
15 seconds after the first chirp.