Status Leds; Table 8-2. Status Leds - High End Systems Studio Spot 250 User Manual

Table of Contents

Advertisement

Status LEDs

The status LEDs help determine where any problems with your Studio Spot 250 or
Studio Color 250 fixture may be originating. See Table 8-2 for a description of the five
status LEDs.
LED
State
Motor
solid green
OFF
Lamp
solid yellow
OFF
flashing
5V
solid red
OFF
Transmit
solid yellow
OFF
flashing
Receive
solid green
OFF
*Note:
If you shut down the lamp using a remote shutdown command, the
lamp and the Lamp LED will shut off. However, if you have bad data
cables, no data cables/controller connected to the fixture, or the
controller is off, the lamp and its LED will also be off. If correcting
these problems does not turn the lamp ON, see the next section.
**Note:
Neither the Transmit nor the Receive LED will be ON until you have
connected the fixture to a DMX 512-compatible controller using XLR
data-grade cabling. If these LEDs remain OFF even though you have
connected the fixture to a controller and are sending DMX 512
commands to the fixture, see the next section.
8-6
Troubleshooting

Table 8-2. Status LEDs

Problem
Indication?
The motor power supply is receiving adequate
No
voltage.
Yes
Fuse or power failure.
The lamp power supply is receiving the proper
No
voltage, and the lamp is ON.
Not necessarily*
The lamp is extinguished.
Yes
The fixture is unable to strike the lamp.
The logic board is receiving the required
No
voltage.
Yes
Fuse or power failure.
Fixture is crossloading software to other fixtures
No
on the link.
Not
No DMX 512 data is being transmitted.
**
necessarily
The fixture is in preset playback mode, and is
No
the master fixture.
The fixture is receiving new software from a
No
crossload or upload.
Not
No DMX 512 data is being received.
**
necessarily
Studio Spot