Laser Aiming Device (Lad™) Troubleshooting; Table 8-5. Lad Troubleshooting - High End Systems Studio Spot 250 User Manual

Table of Contents

Advertisement

Laser Aiming Device (LAD™)
Troubleshooting
Problem
Over time, the laser
The laser gradually
will lose power until it
loses power.
dims out entirely.
The laser is out of
alignment.
The emission
The laser circuit board
indicator LED is off
is not receiving power.
and the laser is off.
The emission
The LAD is not
indicator LED is on,
receiving power.
but the laser is off.
The laser is on, but
The emission
the emission
indicator LED is faulty.
indicator LED is off.
®
Studio Spot
250 / Studio Color

Table 8-5. LAD Troubleshooting

Probable Cause
Contact High End Systems customer service to replace
the LAD (see "Contacting High End Systems" on page
ii).
Realign the laser (see "Aligning the Laser" on page 6-3).
Remove the fixture's bezel and verify that the cable
labeled "LAD" is connected to the fixture's circuit board.
Replace the bezel and use your DMX controller or the
fixture's menu systems to access the laser. If the LED
and laser are still not functioning, contact High End
Systems customer service (see "Contacting High End
Systems" on page ii).
Remove the fixture's bezel and verify that the cable
labeled "LAD" is connected to the fixture's circuit board.
Replace the bezel and use your DMX controller or the
fixture's menu systems to access the laser. If the LED
and laser are still not functioning, contact High End
Systems customer service (see "Contacting High End
Systems" on page ii).
Contact High End Systems customer service to replace
the emission indicator LED (see "Contacting High End
Systems" on page ii).
®