Replacing The Lamp - High End Systems Studio Spot 250 User Manual

Table of Contents

Advertisement

7. Replace the appropriate fuse(s) with a fuse of the same type and rating.
Note:
If you replaced the F3 fuse, reinstall the protective plastic covering
over the fuse.
8. After replacing the fuse, return the display panel to its original position and
tighten the two display panel retaining screws.
9. Replace the two panel covers and tighten the four panel cover retaining
screws.

Replacing the Lamp

Warnings:
Caution:
You will need:
®
• Philips
MSD 250/2, 250 watt, metal halide lamp
• protective gloves and eyewear
• wide tip, flat head screwdriver
To install/replace the lamp:
1. Electrically isolate the fixture. If the fixture has been operating, wait for the
lamp to cool before handling.
2. Put on your protective eyewear and gloves.
7-4
General Maintenance
Disconnect power before re-lamping or servicing.
An operating, unshielded MSD lamp emits ultraviolet and
visible (UV-vis) radiation which could damage eyes and
skin. Whenever you are working on or near an exposed
lamp, wear protective eye gear. Never look directly at the
lamp while the lamp is on.
Hot lamp may be an explosion hazard. Do not open for five
minutes after switching off. Wear eye and hand protection
when re-lamping.
Equipment surfaces may reach temperatures up to 130° C
(266° F). Allow the fixture to cool before handling.
This equipment is designed for use with a Philips® MSD
250/2, 250 watt, metal halide lamp only. Use of any other
type lamp may be hazardous and may void the warranty.
®
Studio Spot
250 / Studio Color
®
250 User Manual