Chapter 8 Troubleshooting; Led Display Error Messages; Table 8-1. Led Error Messages - High End Systems Studio Spot 250 User Manual

Table of Contents

Advertisement

Chapter 8
Troubleshooting
This chapter lists typical symptoms and solutions for problems you might experience
when using your Studio Spot 250 or Studio Color 250 fixture. If you need additional
help, or if the problem you are experiencing is not listed in this chapter, contact High
End Systems customer service in one of the ways shown in the section titled
"Contacting High End Systems" on page ii.
Caution: This fixture must be serviced by qualified personnel. The
information listed in this section is intended to assist qualified
personnel only.

LED Display Error Messages

The Studio Spot 250 or Studio Color 250 menu system provides a comprehensive
listing of error messages when problems occur. If the solution listed in Table 8-1 does
not solve the problem, contact High End Systems customer service (see "Contacting
High End Systems" on page ii).
Display
Message
The fixture was unable to
retrieve the unique DMX start
channel / fixture address. This
error message may be
ADDR
received if you change the
LOST
fixture type (SPOT or COLR)
and cause the fixture's DMX
channel range to overlap
another fixture's channel
range.
A new logic board (without a
stored address) was installed
ADDR
in the fixture or the memory
OVER
location has not been
initialized.
®
Studio Spot
250 / Studio Color

Table 8-1. LED Error Messages

Problem
Set the starting channel / fixture number again (see
"Address Menu (ADDR)" on page 4-20) or contact High
End Systems customer service (see "Contacting High
End Systems" on page ii).
Verify the starting channel or fixture number (see
"Assigning a Fixture Address" on page 2-3).
®
250 User Manual