5. Locate the two lamp
optimization screws (see
Figure 7-24).
6. Loosen the two lamp
optimization screws.
7. Look at the wall where the
beam is projected and use the
two optimization screws to
adjust the lamp's position
within the fixture.
8. When the beam is at its maximum brightness and the light level is even across
the beam (or the "hot spot" of brightness is at the center of the beam),
retighten the two optimization screws to secure the lamp in its new position.

Cleaning the Glass Components

If the glass components of your fixture become dirty, clean them by following the
procedure below.
Warnings:
You will need:
• a soft, lint-free cotton cloth
• mild glass cleaning solution (containing no ammonia)
To clean the internal components:
1. Electrically isolate the fixture. If the fixture has been operating, allow the
fixture to cool before handling.
2. Remove the bezel by unlatching the two bezel latches.
3. Clean the dichroics, lithos, effects, color wheels, and lens using a mild glass
cleaner (containing no ammonia) and a soft, lint-free cotton cloth.
For information on how to access the Studio Spot 250 wheels, see "Replacing
Studio Spot® 250 Wheel Components" on page 7-7. For information on how
to access the Studio Color 250 wheels, see "Replacing a Studio Color® 250
Wheel" on page 7-13. For information on how to access the lens, see
"Replacing the Lens" on page 7-16.
7-20
General Maintenance
Disconnect power before servicing.
Equipment surfaces may reach temperatures up to 130° C
(266° F). Allow the fixture to cool before handling.
lamp optimization
screws

Figure 7-24. Lamp optimization screws.

®
Studio Spot
250 / Studio Color
®
250 User Manual