Display
Message
• The pan motor wire has
PAN DRV
shorted to ground.
ERR
• Bad pan driver chip.
• The pan encoder sensor is
PAN
not connected.
ENCD
• The pan encoder is not
functioning properly.
• Loose pan pinion gear.
• Loose pan motor cable.
• Incorrect cabling to pan
PAN ERR
input.
• Bad pan sensor.
• Bad pan motor.
• There is a physical
obstruction blocking pan
PAN
movement.
STOP
• The pan encoder is out of
calibration.
The maximum allowed
programming time was
PRGM
exceeded during an upload
TIME
due to:
• Incomplete data.
• Bad board.
Preset scenes stored on the
PRST
fixture's on-board memory
LOST
were lost.
SENS
Problem with the tab, sensor or
ERR
motor on the specified sensor.
There was a sensor error due
SVCC
to:
ERR
• Bad board
• Loose cable
THRM
The microprocessor maximum
CHIP
temperature was exceeded.
8-4
Troubleshooting
Table 8-1. LED Error Messages
Problem
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
• Try the upload again (see "Uploading Software to the
Fixture" on page 3-15).
• Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
An electrical event may have interrupted or corrupted
preset scene data. Try manually entering the preset
scene or contact High End Systems customer service
(see "Contacting High End Systems" on page ii)
• Run a self-test on the specified sensor (see
"Performing Self Tests (SELF)" on page 4-31).
• Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
• Move the fixture if it is close to a heat source.
• Remove any object which may be obstructing the
fixture's heatsink.
• Check and reduce ambient temperature by turning on
fans, etc.
®