Display
Message
THRM
The pan motor maximum
PAN
temperature was exceeded.
THRM
The tilt motor maximum
TILT
temperature was exceeded.
TILT
The tilt sensor is not connected
CONN
• The tilt motor wire has
TILT DRV
shorted to ground.
ERR
• Bad tilt driver chip.
The tilt encoder is not
TILT
connected or not functioning
ENCD
properly.
• Loose tilt pinion gear.
• Loose tilt motor cable.
TILT ERR
• Incorrect cabling to tilt input.
• Bad tilt sensor.
• Bad tilt motor.
• There is a physical
obstruction blocking the tilt
TILT
movement.
STOP
• The tilt encoder is out of
calibration.
The fixture is held in boot mode
UPLD
because power was
disconnected during an upload.
®
Studio Spot
250 / Studio Color
Table 8-1. LED Error Messages
Problem
• Move the fixture if it is close to a heat source.
• Remove any object which may be obstructing the
• Check and reduce ambient temperature by turning on
• Move the fixture if it is too close to a heat source.
• Remove any object which may be obstructing the
• Check and reduce ambient temperature by turning on
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Contact High End Systems customer service (see
"Contacting High End Systems" on page ii).
Remove the obstruction and home the fixture.
Reconnect the fixture and perform the upload again or
contact High End Systems customer service (see
"Contacting High End Systems" on page ii)
®
250 User Manual
Solution
fixture's heatsink.
fans, etc.
fixture's heatsink.
fans, etc.
Troubleshooting