Replacement Fuses; Replacing The Lamp - High End Systems SHOWGUN User Manual

High end system showgun user's manual
Hide thumbs Also See for SHOWGUN:
Table of Contents

Advertisement

CHAPTER 5
Maintenance and Troubleshooting
Fuse
3-phase
One fuse plus one extra on the each board Pan or Tilt board-related motors and
driver boards
LED Control
One Fuse
Board

Replacement Fuses

Fuse
Motor Power Supply Input
Motor Power Supply Output
2-phase Driver Boards
3-phase Pan and Tilt Board
LED Control Board
Lamp Power Supply Input

Replacing the Lamp

RISK OF EXPOSURE TO EXCESSIVE ULTROVIOLET (UV) RADIATION:
Change shields and lenses if they have become visibly damaged to such
an extent that their effectiveness is impaired, for example by cracks or
deep scratches.
Never look directly at the lamp while lamp is on.
Do not operate without complete lamp enclosure in place or when lens
is damaged. Serious injury may result from the generation of ozone by
this lamp system. A proper means of venting must be provided.
RISK OF POSSIBLE LAMP EXPLOSION:
Do not open for five minutes after switching off.
Service and maintenance should be performed only by qualified
personnel as determined by the high-pressure lighting fixture
manufacturer.
Wear eye and hand protection when re-lamping.
DANGER-INTENSE HEAT:
Equipment surfaces may reach temperatures up to 150° C (302° F).
Allow the fixture to cool before handling.
This equipment is designed for use with a Philips® MSR Gold SA/SE
metal halide lamp only. Use of any other type lamp may be hazardous
and may void the warranty.
38
Fuse Location and Access
Fuse Type and Rating
2.5 A, 250 V, Slow Blow
5 A 250 V, Slow Blow
2.5 A, 125 V, Slow Blow SMF
5A, 125V, Slow Blow SMF
20A, 250V, Very Fast
Symptom of Failure
fans will be off.
LEDs won't light
Manufacturer HES Part Number
Littelfuse
Littelfuse
Littelfuse
Littelfuse
Bussmann
SHOWGUN
90403027EF
90403012EF
90402016EF
90412027EF
90403030EF
®
User Manual