Test 3: Measure Ac Voltage Output Of Each Stator Leg At Charging Rpm; Stator (Alternator) Replacement; Regulator / Rectifier Operation - Polaris GENERAL 2016 Service Manual

Table of Contents

Advertisement

ELECTRICAL
CONNECT
TEST
LEADS TO:
Battery Charge
Y1, Y2, or Y3
Coil
TEST 3: MEASURE AC VOLTAGE OUTPUT OF
EACH STATOR LEG AT CHARGING RPM
1. Set the selector dial to measure AC Voltage.
2. Start the engine and let it idle.
3. While holding the engine at a specified RPM,
separately measure the voltage across each 'leg' of
the stator by connecting the meter leads to the wires
leading from the alternator (Y1 to Y2, Y1 to Y3, Y2 to
Y3).
4. Refer to the following table for approximate AC
Voltage readings according to RPM. Test each leg at
the specified RPM in the table.
5. Example: The alternator current output reading
should be approximately 21 VAC ± 25% at 1300 RPM
between each 'leg'.
6. If one or more of the stator leg output AC voltage
varies significantly from the specified value, the stator
may need to be replaced.
RPM READING
1300
3000
5000

STATOR (ALTERNATOR) REPLACEMENT

Refer to "Stator Cover Removal / Inspectionpage
3.45" for stator service.
NOTICE
The stator cover can be removed with the engine
installed in the chassis.
Be sure to thoroughly clean the area around the stator
cover prior to removal.
11.68
OHMS
METER
READING
Open Line (OL
/ ∞)
to Ground
AC VOLTAGE (VAC)
READING
21 VAC ± 25%
47 VAC ± 25%
79 VAC ± 25%

REGULATOR / RECTIFIER OPERATION

The regulator / rectifier is mounted behind the front
bumper.
9929375 R02 - 2016-2019 GENERAL / GENERAL 4 Service Manual
© Copyright Polaris Industries Inc.

Advertisement