8. Turn the door cable adjuster clockwise until the door
latch opens.
NOTICE
The adjuster will be moving away from the lock collar
when tightening the cable.
9. Mark the top of the adjuster with a paint pen.
10. Turn the adjuster clockwise an additional 3–4 turns in
relation to the paint mark.
11. Push door latch into double lock position.
12. Open exterior door handle slowly.
NOTICE
The exterior door handle should be about 3/4 of the way
through its throw when it releases the latch. Adjust
cable if necessary.
13. When cable is adjusted properly tighten lock collar.
14. Locate interior door cable adjuster.
15. Push door latch into double lock position.
9929375 R02 - 2016-2019 GENERAL / GENERAL 4 Service Manual
© Copyright Polaris Industries Inc.
16. Loosen M10 nuts on either side of cable.
17. Hold the interior door handle in the full open position.
18. Tighten the M10 nut on the door latch side until the
door latch fully opens.