If you forget to Move the
Lock/Unlock Lever Back
! This could cause a problem if power is turned off
accidentally during copying.
" If this occurs, the drawer unit can be pulled out,
but the user may not be able to push it back in
because the fusing unit is still pressed up by the
cam.
" To cure this problem, see the final part of the
"Removing the Fusing Unit" procedure.
Slide 500
# The cam in the pressure roller lift mechanism must be reset. The procedure in
the service manual shows you how to do this.
V-C3 field service manual, Removal and Adjustment, Fusing
500
Unit, Removing the Fusing Unit