Ricoh V-C3 Technical Training Manual page 535

Advertisement

2.2 Overview – 2 (System Settings)
1) Timer settings and recovery time (System settings => Timer setting)
Mode
Panel off Mode
Low Power Mode
Off/Sleep Mode
Specified values for timers
Panel Off > Energy Saver > Auto Off
Panel Off = Energy Saver = Auto Off
Panel Off < Energy Saver < Auto Off
2) Energy saver level setting (System setting => Administrator Tools => Energy saver level )
Level 1
Level 2
Slide 535
# ・Energy Saver Level
# The user can set these timers with User Tools
MFP/ Priport: User Tools > System settings > Timer Setting
Printer
: User Tools > System settings > Energy Saver Timer
# Normally, Panel Off timer < Energy Saver timer < Auto Off timer.
# But, for example, if Auto Off timer < or = Panel Off timer and Energy Saver timer,
the machine goes immediately to Off mode when the Auto Off timer expires. It
skips the Panel Off and Energy Saver modes.
# Example
$ Panel off: 1 minute
$ Low power: 15 minutes
$ Auto Off: 1 minute
$ The machine goes to Off mode after 1 minute. Panel Off and Low Power
modes are not used.
# We recommend that the default settings should be kept.
$ If the customer requests that these settings should be changed, please
explain that their energy costs could increase, and that they should consider
the effects on the environment of extra energy use.
$ If it is necessary to change the settings, please try to make sure that the
Auto Off timer is not too long. Try with a shorter setting first, such as 30
minutes, then go to a longer one (such as 60 minutes) if the customer is not
satisfied.
$ If the timers are all set to the maximum value, the machine will not begin
saving energy until 240 minutes has expired after the last job. This means
that after the customer has finished using the machine for the day, energy
will be consumed that could otherwise be saved.
$ If you change the settings, the energy consumed can be measured using
SP8941, as explained later in this presentation.
2. Energy Saving
Power
Consump.
Warm-up
Operation Mode
Ready Mode
Panel Off Mode
Low Power        Mode
Off/Sleep        Mode
Plug-in
Timer
Defult
Setting range
Panel Off Timer
60 sec.
10 sec to 240 min.
Energy Saver Timer 15 min.
1 to 240 min.
Auto Off Timer
30 min.
1 to 240 min.
Panel Off
Low Power
Can start
Can start
Cannot start Cannot start
Cannot start Cannot start
Panel off only
Panel off and lower the fusing temperature to recovery time within 10sec.
535
Recovery time
3 sec.
45 sec.
a:90, b:75 sec
Auto Off
Can start
Can start
Can start
V-C3 Training