Temperature/Humidity Sensors
! There are three of these.
" Above the magenta PCU (machine internal
" Near the waste toner bottle motor (room
" In the laser optics unit, two sensors
Slide 222
No additional notes
temperature)
» Corrects the charge applied to the charge roller
» Adjusts the length of time that the developer is agitated
temperature)
» Corrects the charge applied to the ITB and PTR
» Corrects the fusing temperature
» Adjusts the length of time for fusing idling
» Used for the MUSIC process, to prevent color registration
errors