Download Print this page

Ricoh V-C3 Technical Training Manual page 88

Advertisement

If the Bottles are not Empty - 1
! First, check you removed the tapes and that the bottles are
attached correctly.
! Use SP3814 again.
" Do SP3814-1 to 6 for the color of whichever PCU is to be
filled with developer.
» These SP codes fill the PCUs with developer from the
developer bottle.
" Hold the bottle to prevent it from coming off, then tap the
bottle gently a few times.
" Open the front door, then turn on the main power switch.
" When you see the door open message on the screen, close
the door.
" Wait about 40 sec. until the SC code appears on the
screen, then turn off the power switch.
" Repeat this procedure until the bottle becomes empty.
" After 10 attempts if the bottle is still not empty, do the
procedure on the next slide.
Slide 88
V-C3 field service manual, Removal and Adjustment, PCU,
Developer Replacement, Handling Problems with Developer
88
V-C3 Training
Filling